ラップトップで有線の問題が発生しています。正常に動作しますが、ほぼ1時間ごとに画面がフリーズします。強制的にシャットダウンしてもう一度起動すると、次のような問題が発生します: ここに画像の説明を入力してください

私が見つけた唯一の解決策は、ラップトップを数秒間裏返してから再起動することです。これにより、これらのFSの問題がなくてもUbuntuが正常に動作することを確認できます。

更新:これはsmartctlの出力です:

smartctl 6.5 2016-01-24 r4214 [i686-linux-4.15.0-32-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Laptop SSHD Device Model: ST500LM000-SSHD-8GB Serial Number: W761F5WC LU WWN Device Id: 5 000c50 07c440eb8 Firmware Version: LIV5 User Capacity: 500 107 862 016 bytes [500 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS, ACS-3 T13/2161-D revision 3b SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Aug 17 14:37:51 2018 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 128) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 96) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x1081) SCT Status supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 114 099 034 Pre-fail Always - 81759080 3 Spin_Up_Time 0x0003 098 098 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 097 097 020 Old_age Always - 3865 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 072 060 030 Pre-fail Always - 163745195646 9 Power_On_Hours 0x0032 080 080 000 Old_age Always - 17649 (115 151 0) 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 096 096 020 Old_age Always - 4175 184 End-to-End_Error 0x0032 096 096 099 Old_age Always FAILING_NOW 4 187 Reported_Uncorrect 0x0032 098 098 000 Old_age Always - 2 188 Command_Timeout 0x0032 100 094 000 Old_age Always - 25770197149 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 058 036 045 Old_age Always In_the_past 42 (Min/Max 42/46 #389) 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 1213 193 Load_Cycle_Count 0x0032 098 098 000 Old_age Always - 4834 194 Temperature_Celsius 0x0022 042 064 000 Old_age Always - 42 (0 12 0 0 0) 196 Reallocated_Event_Count 0x000f 080 080 030 Pre-fail Always - 17711 (44104 0) 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 7 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 7 occurred at disk power-on lifetime: 16948 hours (706 days + 4 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 08 ff ff ff 4f 00 00:00:25.320 READ FPDMA QUEUED 60 00 20 ff ff ff 4f 00 00:00:25.319 READ FPDMA QUEUED 60 00 60 88 da 7f 41 00 00:00:25.309 READ FPDMA QUEUED 60 00 20 ff ff ff 4f 00 00:00:25.288 READ FPDMA QUEUED 60 00 08 ff ff ff 4f 00 00:00:25.284 READ FPDMA QUEUED Error 6 occurred at disk power-on lifetime: 966 hours (40 days + 6 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 10 c5 a5 00 Error: UNC at LBA = 0x00a5c510 = 10863888 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 08 88 79 42 43 00 00:00:18.239 READ FPDMA QUEUED 60 00 08 80 79 42 43 00 00:00:18.239 READ FPDMA QUEUED 60 00 a8 10 c8 84 40 00 00:00:18.237 READ FPDMA QUEUED 60 00 08 78 79 42 43 00 00:00:18.237 READ FPDMA QUEUED 60 00 00 e0 c6 84 40 00 00:00:18.237 READ FPDMA QUEUED Error 5 occurred at disk power-on lifetime: 966 hours (40 days + 6 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 10 c5 a5 00 Error: UNC at LBA = 0x00a5c510 = 10863888 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 28 00 48 f8 40 00 00:00:13.615 READ FPDMA QUEUED 60 00 08 08 0e 44 40 00 00:00:13.609 READ FPDMA QUEUED 60 00 18 60 d0 e6 40 00 00:00:13.608 READ FPDMA QUEUED 60 00 08 b8 a8 e6 40 00 00:00:13.608 READ FPDMA QUEUED 60 00 28 10 9b e6 40 00 00:00:13.607 READ FPDMA QUEUED Error 4 occurred at disk power-on lifetime: 32 hours (1 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 76 9d b6 01 Error: UNC at LBA = 0x01b69d76 = 28745078 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 80 60 9d b6 41 00 00:01:10.856 READ FPDMA QUEUED 61 00 08 68 89 59 40 00 00:01:10.747 WRITE FPDMA QUEUED 61 00 08 88 f6 3c 40 00 00:01:10.747 WRITE FPDMA QUEUED 2f 00 01 10 00 00 20 00 00:01:10.494 READ LOG EXT 60 00 40 c8 25 4c 41 00 00:01:10.441 READ FPDMA QUEUED Error 3 occurred at disk power-on lifetime: 32 hours (1 days + 8 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 76 9d b6 01 Error: UNC at LBA = 0x01b69d76 = 28745078 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 80 60 9d b6 41 00 00:00:53.242 READ FPDMA QUEUED 61 00 80 40 ba 44 41 00 00:00:53.241 WRITE FPDMA QUEUED 61 00 10 10 f7 86 40 00 00:00:53.241 WRITE FPDMA QUEUED 60 00 40 98 b7 1e 42 00 00:00:53.216 READ FPDMA QUEUED 60 00 08 60 9d b6 41 00 00:00:53.169 READ FPDMA QUEUED SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Vendor (0x50) Completed without error 00% 1 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. 

問題を修正するために起動時にFSCKを作成しましたしかし、それは役に立ちませんでした。解決策はありますか?

コメント

  • ハードウェアエラーのようです:質問を編集できますかsmartctl --all /dev/sdaの出力を追加してください。今すぐ完全バックアップを作成してください。 はい、つまり、HDDに障害が発生しているようです!
  • @Fabbyの回答に感謝します。 '今すぐsmartctl出力を追加します。
  • 'この種の問題は、月。 End-to-End_Error askubuntu.com/a/789063/206714 に関する回答を見つけましたが、どうすればよいですか?

回答

すぐにバックアップ

追加の外付けHDD / SSDを購入し、完全な CloneZilla Live のバックアップを今すぐ!ドライブが故障の差し迫った危険にさらされているという死んだプレゼントは、次のパラメータです。

184 End-to-End_Error 0x0032 096 096 099Old_age常に FAILING_NOW 4

特にこの問題が1か月間発生している場合現在: HDDはすぐには停止しないことが知られていますが、クリック音やランダムエラーなどの十分な警告が表示されますが、SSDは、SMARTステータスを定期的に測定しない限り、警告なしに突然停止します。

ドライブの大まかなルールは次のとおりです。

  • HDDは癌のようにゆっくりと痛みを伴う死に至ります
  • SSDは心臓発作のように突然死に至ります

コメント

  • 他の'が述べているように、'これが当てはまるかどうかを判断するのに十分な証拠はありません。ドライブをすぐにバックアップすることをお勧めします。
  • @slm:数回編集しました。まだ印象を受けていますか?は予感であり、具体的なデータによってバックアップされていませんか?

回答

回答できません。

システムが不安定で、適切にシャットダウンできない場合、ファイルシステムエラーが(クラッシュ時のディスクアクティビティに依存するため、ランダムに)表示されるのは正常と見なされます。

これはファイルシステムの問題ではなく、fsckの問題でもありません。最初に、システムがフリーズする原因となっているものを修正する必要があります。

コメント

  • お詫び:同意しません。 コメントおよび回答 ¯ \ _(ツ)_ / ¯
  • @Fabbyは、SMART出力がなければ、決定的なものになることは不可能でした。

回答

smartctlの出力によると、ドライブは が現在失敗しています

すべてのバックアップを個別に作成します。以前のバックアップを上書きしないでください(一部のファイルはすでに破損している可能性があるため、適切なバックアップを上書きしたくありません)。

次に、ドライブを新しいものと交換し、新しいバックアップと最後のバックアップの比較を開始します。どれだけ破壊されたかを確認するための既知の適切なバックアップ。

コメントを残す

メールアドレスが公開されることはありません。 * が付いている欄は必須項目です